Equipment

Flyer

IME has a broad variety of modern equipment available. A virtual tour is being created at the moment. To inform yourself on a specific area, you can download our information brochures below.

PDF
1 IME (Introduction)
2 Vacuum Metallurgy
3 Recyclingmetallurgy

Molten salt electrolyse
Application area :
  • Production of titanium, titanium alloys and rare earth  by molten salt electrolyse
  • Carrying out electrochemical measurements
  • Continuous FT-IR gas analysis
Performance data:
  • Temperature range: up to 1200 ° C
  • Volume: 800 ml electrolyte
  • Possible gas atmosphere: N2, Ar, air
  • Voltage measurement range: up to 10 V
  • Current measurement range: up to 40 A
  • Munk rectifier: up to 200 A and 30 V
  • Yokogawa recorder: measures U, I, J, T
  • Yokogawa Controller: programming for individual control of the electrolysis process
Contact person: M. Sc. Dominic Feldhaus


Last update: 12.16.2019